Education plays a huge role in all of our lives, from when we start our first days in education ourselves, through to bringing new talent into the working world, and even teaching our children. However, with the world becoming ever more digital, our learning environments must evolve. By embracing technology, schools, already under immense pressure can leverage digital tools to enhance critical elements such as teaching, collaboration, and even marking. With the rise of educational platforms like Google Classroom, Microsoft Teams, Kahoot, Tinkercad, and Scratch, schools are seeing levels of network demand that were previously unheard of. With so many tools now dependent on internet connectivity, is your school’s network infrastructure keeping up, or is it silently undermining your students’ learning outcomes? The Hidden Cost of Poor Infrastructure With digital technologies underpinning so much now in the classroom, the true cost of poor infrastructure is starting to show within many schools, colleges and universities across the country. Lack of Wi-Fi signal coverage or poor Wi-Fi configuration can lead to frequent disconnections and poor response times, which can be crucial with certain applications such as Kahoot or streaming. However, poor network configuration or limited bandwidth can cause huge delays in accessing cloud documents, this is especially key in todays cloud-first approach that many schools have adopted. While these are frustrating for teaching staff and IT Staff alike, they are also frustrating and disrupting for pupils, with lost teaching time and students becoming disengaged. The Ultimate Digital Infrastructure The Department for Education (DfE) has laid out their recommendations for network infrastructure, within schools and colleges and whilst this is a good baseline, each schools requirements can vary signifcantly, depending on the age, layout and priorities of each school. At Nene Data Network Solutions, we find that many educational facilities are promoting a Wi-Fi first approach, with IT Suites being removed and pupils going laptop based. In these environments we always start with a comprehensive Wi-Fi survey, followed by a tailored Wi-Fi design as required. However, Wi-Fi is only as good as the wired infrastructure that supports it. The Department for Education suggests that Copper cabling should be Category 6A, this is among the highest standards available in the UK and we promote this standard, especially for Wi-Fi installations, allowing for 10Gb Ethernet on each link. However, it is not a one size fits all, and we commonly find Category 6 being suitable for many schools, due to its lower size and cost. Providing a high bandwidth, 10Gb Ethernet link to access points and other client devices is only worthwhile however if the backbone and switching can support it, therefore multi-Gigabit switches should be deployed and a thoroughly designed, divergent fibre backbone is essential. Whilst the Department for Education recommend 16 Core OM4, we often find a mixture of OM4 and OS2 is beneficial for schools, colleges and universities. Strengthening School Infrastructure with Built-In Cybersecurity With cyber threats on the rise, it is important not to forget about the cybersecurity elements of the schools network. The Department for Education is urging both colleges and schools alike to work to adhere to Cyber Essentials. At Nene Data Network Solutions, we work with educational facilities natiownide in helping them meet the requirements by deploying both Wired and Wireless Solutions that are secure, scalable and compliant. A well configured infrastructure is the first line of defence against data breaches, misuse and operational disruption. There are a number of key ways we deploy infrastructure that supports cybersecurity, from network segmentation and device authentication to real time monitoring and Rule Based Access Control. Ready to Rethink Your School’s Network? The digital classroom relies on more than just the end user devices, it truly depends on the invisible infrastructure behind the scenes. If you’re unsure if your network is supporting or holding back learning, we’re here to help. From actionable assistance, to on-site consultancy, get in touch today with our team for a no-obligation chat with one of our consultants. About the Author Joshua Passmore Technical Director Joshua Passmore is our Technical Director, he’s been part of the NDNS Team since 2015. He heads up our Technical Solutions and has a real soft spot for Wireless Technologies.
The latest news within the network infrastructure industry
Categories
What is CPR? What does it mean for Network Cabling?
The Construction Products Regulation is a European Union directive, set out with an intention of making buildings, safer. It brings us a standard classification system for how construction products react to fire. Categorising them into groups (EuroClasses). Ahhh, yep it had to be said, oops… No, Brexit will not affect the implementation of CPR. Why? Well, CPR provides us with the EuroClasses and how cables should be tested to categorise them. It doesn’t however, state, what the minimum class of cable should be, for each environment. However, the 30th November 2017 saw a big change. BS 6701 (a British Standard) was amended and EuroClass Cca, S1b, d2, a2 was implemented as the minimum class of cable that should be used in a permanent installation. This has now been written into British Standards, so Brexit is unlikely to have any effect moving forwards. In simple terms, any cable that is installed in a fixed installation is required to apply by the Construction Products Regulations. This could be anything from power cabling to control and communications cabling. It does, however, not apply to things such as patch leads. We know that BS6701 has specified Cca, S1b, d2, a2, but what on Earth does that gibberish mean? CPR specifies that the code is constructed in the following manner: This test establishes how a cable contributes to the fire. There is a range between Aca (not contributing) all the way to Fca (undetermined). B1ca – B2ca provides a minimum contribution to fire. Whilst Cca, Dca & Eca are combustible and do contribute to the fire from a lower to higher contribution (lower letter means less contribution). The next part of the code is based on the smoke emission properties of the cable. s1, s1a & s1b both provide little smoke production and a slow smoke propagation. s2 produces an average amount of smoke and propagation s3 provides none of the above and is a worst case. Burning droplets are the next thing that the EuroClass classifies. There are three classifications, d0, d1 & d2. d0 provides no burning droplets. d1 provides no burning droplets for more than 10 seconds. d2 is for cables that do not fit into either of the above criteria. During a fire, cables can give off an acidic gas. The last part of the EuroClass code grades this between a1 and a3. a1 is for cables that reach a conductivity of < 2,5 μS/mm and pH > 4,3. a2 is for cables that reach a conductivity of < 10 μS/mm and pH > 4,3. a3 is for cables that do not meet any of the prior specifications. Cables now run everywhere. With a large number of devices being networked, from users PCs and Telephones to Access Control, Wi-Fi and CCTV. Network cables have become much more versatile. And all this doesn’t just mean an increase of copper cabling, to support the growing bandwidth demands, fibre optic cables are increasingly being installed between areas and floors within a building. What this does provide is a path for fire. And with standards such as 802.3bt being ratified, your existing copper cabling could be expected to carry up to 100W of power, further increasing the risk of fire if the installed cable isn’t designed for such a use. Everybody is affected by CPR. Manufacturers are required to ensure their products are tested in accordance to the array of standards. Specifiers are required to ensure their specifications clearly state the minimum EuroClass, appropriate to the country, standards bodies and ultimately the client. Installers, like us, need to ensure that what we install is in-line with the specification laid out or where this isn’t present, what the client wants. If you’re a client or end-user, you should asses using the above, what cable specification meets the requirements of your sector best. Where you are unsure, please do get in contact and our will be happy to help. Once you’ve established what classification of cable best suits your needs, ensure that on the completion of the installation you are provided with a Declaration of Performance for the cable. You would expect this as part of your Operations & Maintenance Manual. If you decide to choose a higher EuroClass of cable, it’s important to double check the CSA (Cross-Sectional Area) of the cable. Usually, the higher the fire rating, the larger the cable. This can mean in larger quantities, larger cable containment needs to be considered, this is especially important if you have opted for a three-compartment containment system. Be sure to check with the containment manufacturer. If you think like us, you’re probably asking yourself why not just make everything super safe? We agree! However, it does come at quite a cost premium… Whilst it will depend on the cabling system chosen and your installer, cable costs can be upwards of 40% between Eca & Cca classifications. This is a huge increase, especially on a larger install. We feel it’s important to remember that CPR cables are still fairly juvenile and we should hopefully see a reduction in price as time goes on. It’s definitely clear that CPR isn’t something we can ignore, especially if you want to be standards compliant and ensure the safety of your visitors and staff. Many cable vendors have re-designed their product lines to accommodate a wide range of CPR Compliant cables. We think there’s certainly more to come, especially with such a wide range of cables on the market. If you did want to talk to someone regarding the latest developments or you want a second opinion on what cable suits your needs best, please get in touch with one of our advisors on 01604 422722 or message us via our live chat!
F/UTP, U/FTP, S/UTP, U/UTP – What Are They?
If the variation in categories of Copper Cabling weren’t enough, don’t worry because the different configurations bring more headaches and decisions to make… Cables come either screened or unscreened, and most installations use simple unscreened balanced copper cabling. However, there are multiple options for screening available, adding complexity, each bringing something slightly different to the table… There are two forms of shielding set out in ISO/IEC 11801, foil screen and braid screen. What is the Difference between Foil and Braided screening? Screening is used/specified in environments where EMI is a concern. An overall shield provides a conductive barrier to attenuate any electromagnetic waves external to the cable. However, shielding also provides a path where induced currents can be safely taken to a grounding point (at a termination point). Foil Screening Foil Screening/Foil Shielding is usually a slim piece of aluminium, providing total coverage. The main benefit of the foil screening is the fact it provides total coverage; there are no gaps in its protection. Because the foil is thin, it makes the cable flexible and doesn’t greatly add to the diameter of the cable (CSA / Cross-Sectional Area) subsequently meaning significantly larger containment does not need to be installed. Sadly because it is quite thin, the cables protection does have a low flex life and it’s not hugely durable. It also provides no mechanical strength. Advantages Disadvantages Braided Screening Braided Screening, unlike foil screening, uses a tightly woven lattice of thin wires, usually tin or copper. Compared to foil screening, it offers a great amount more of mechanical protection, because it is harder wearing, it’s flex life is also greatly improved. These do however come at disadvantages, because of the woven lattice there is gaps present within its protection meaning overall protection isn’t achieved like foil screening. And due to its harder wearing qualities, it is a lot bulkier. Slightly reducing the cables flexibility and giving the overall cable a slightly larger diameter (CSA). Advantages Disadvantages The Different Shielded Options Now we understand the different materials used to provide shielding, we can look at the different options. To ensure all cable manufacturers are talking about the same specification of cable, ISO/IEC 11801 implemented Annex E and introduced the following schema. Operating on the above schema, there are 6 common cable forms. Lets take a look U/UTP Keeping it simple at first, U/UTP, or UTP for short. Following the above format, this cable is not screened at all. It’s the most common installed cable, the cable is flexible and keeps the CSA to a minimum lowering the requirements for expensive large containment. U/FTP Providing some screening, in U/FTP, or FTP for short there is a screen around each individual pair. Unlike an overall screen, the screening inside the cable helps to minimise crosstalk from within the cable itself. This is commonly found within high-frequency cables such as Category 6A. F/UTP FUTP, like UFTP is also sometimes referred to as FTP. Unlike U/FTP, its screening isn’t for each pair and just wraps entirely around the cable, encompassing all 4 pairs under one overall screen. This aids against mitigating external influences causing EMI, this can be from a range of different devices but also other cables that are bundled together. SF/UTP Pulling out all the stops is SF/UTP. Combining both braided screening and foil screening into one cable provides the benefits of both. Usually found in high interference environments, both foil and braid provide an overall shield with the pairs left unscreened. It’s uncommon to see SF/UTP used in high frequency cables such as Category 6 and above, this is due to the lack in individual pair screening. Therefore, it’s most commonly found in Category 5e cabling where huge bandwidth requirements aren’t present however the integrity of the signal is. S/FTP Moving the foil screen to between the pairs is S/FTP. Much like SFUTP, SFTP is designed for high interference environments where external influences are a concern. But unlike SF/UTP, also a concern crosstalk between the pairs. For this reason, it’s much more likely to be found in Category 6 and above cables. Due to the braided screening, S/FTP cabling is usually found in installations where the cables diameter isn’t of huge concern and the cable doesn’t require huge amounts of flexibility. F/FTP Where F/FTP proves it’s worth is in high density applications. In installations where both crosstalk and alien crosstalk are concerns yet cable capacity and containment are also, F/FTP is used. Because it lacks the braiding, the diameter of the cable isn’t hugely increased and nor is the flexibility, however that doesn’t compromise it’s screening abilities. Shielded Cabling & PoE? While we’ve been through the EMI and mechanical strength that the various braided and shielding options bring, we have neglected to mention PoE. PoE has become a buzzword for the industry. Hugely gaining traction, Power over Ethernet (PoE) allows you to power remote devices such as IP Phones, CCTV Cameras and Lighting with the same cable that provides the network connection. I’m sure you’re wondering what that has to do with shielding… Well along with larger conductor sizes, shielding being present aids the installed cable is keeping cool. Through laboratory testing, it’s been established that the presence of a metallic braid or foil helps to dissipate the heat. Therefore, while it’s not the only thing you should consider when implementing a PoE ready network, a shielded system should be high on your list of considerations. To Conclude It’s obvious that shielding through its various means provides potentially huge benefits. However, it does come with it’s set of challenges, especially when considering the termination and containment of the cabling. And whilst it’s great to have a wide variety of options available… it becomes a little bit of a minefield! Therefore, if you decide that shielded cabling is really what you need, but perhaps want some guidance in what form suits your requirements. Give one of our team a call on 01604 422722, we’d be more than happy to help!
Category 5e, 6, 6A, 7, 8? – What’s the Difference?
There are a vast array of revisions to the ethernet cable; each an improvement on their predecessor – But what is the difference between them? Take a look below for a brief explanation on the differences between common ethernet cables. Common Features Despite there being lots of revisions of ethernet cable, they all share some fundamental common features.For example: Category 5e / Class D Category 5e (short for Category 5 Enhanced) was ratified in 2001 and replaced Category 5. It was built on the foundations that Category 5 laid down. Category 5e operates at 100MHz, much like Category 5 did. However, Category 5 was only ever designed for 10/100Mb applications. Cat5 was officially superseded in 2001 and is no longer manufactured or commonly found. But what improvements did Category 5e bring? Firstly, it brought gigabit support (1000Mb). This helped give network devices a considerable increase in bandwidth availability. To enable it to do this, it reduced crosstalk by increasing the twist rate of the pairs inside the cable. To this day, Category 5e is still installed within business networks. With up to Gigabit transmission speeds, it is still suitable for a large number of applications such as printers, PDQ machines etc. Although for companies that are installing for the future, we’re seeing a rise in Category 6 and above being specified. Cat5e cable comes in both U/UTP & F/UTP forms, both offering distinct differences and suiting different applications. With the ratification of 802.3bz (What is 802.3bz?), there is an aim to support 2.5G over Category 5e however, when (and IF) we may see this in the real world, is still up for debate. Category 6 / Class E Taking Cat5e up a notch, we have Cat6 Cabling running at 250MHz. The largest differences between Category 6 and Category 5e is conductor size, and an internal spline (separating member). These differences allow Cat6 to minimise crosstalk and support up-to a 10G throughput (55m max channel length). However, it’s worth remembering that the 55m is a maximum limit and the quality of the installation is the limiting factor, when specifying purely for a 10G network Category 6A is best suited. Category 6 cable, much like Cat5e can be bought in both U/UTP & U/FTP varieties – And it’s also backwards compatible, operating at 10/100/10000Mbs where required. Category 6A / Class Ea We’re starting to see a rise in workstations shipping with 10G NICs. If you want a network infrastructure to support these and future high-bandwidth devices, Category 6A is your safe bet. Category 6A operates at a much higher, 500MHz frequency. Designed for 10G applications from day dot (unlike its predecessors), it improves hugely on alien crosstalk, which Cat6 struggled with at high frequencies. Category 6A comes in a wide range of varieties. All the way from U/UTP, to S/FTP. We wouldn’t recommend U/UTP purely because of the popularity in PoE and the fact it is usually just as expensive as F/UTP. F/UTP and higher designs are much better at heat dissipation and aren’t as susceptible to alien crosstalk. Supporting 10G of bandwidth, up to a maximum channel length of 100m – It is also able to support the theoretical throughput of the latest wireless access points. Most organisations feel that Category 6A will support most of their business needs for years to come, and therefore commonly this is the highest cable you’ll likely see. Category 7? Category 7A? / Class F(a) You may question the question marks… Cat7 and Cat7A is a technology that hasn’t taken off quite as much as everyone expected. Firstly, it has never been recognised in the TIA/EIA-568 standard. That’s fairly major… It also has three recognised connector types, all of which aren’t the common RJ45… GG45, ARJ45 & TERA. The reason for the variation on the connector type comes down to one very simple complexity, crosstalk. With Class F(a) providing up to a huge 1000MHz, crosstalk proved to be an issue at the connector end. With the standard RJ45, 8P8C connector, all the pins are placed right next to one another, allowing for crosstalk to manifest, and at these frequencies it proved to be troublesome. For this reason, different connector types were pursued, however this fatally flawed the easy backwards compatibility that previous classes allowed. For this reason, we’ve never seen the addition of Class F, or Class Fa for that matter within TIA/EIA-568. And although it’s still within the ISO Standards, its lack of truly backwards compatible connector has hindered it’s jump into common use. Until we see hardware such as switches & NICs being shipped with a connector that is supported, we likely won’t see a true take off of Cat7 cabling. Category 8 There are now initial movements of Category 8 from the leading cable vendors. Supporting a huge 2000MHz and speeds of up to 40Gbps. However, in the ISO/IEC standards, there are two separate classes and two separate cables to support them. Category 8.1 supports Class I. Category 8.2 supports Class II. Unlike Cat6a, there is no unshielded variety. Only Category 8.1 is compatible with the RJ45 connector, and therefore we feel that it shall be used the most. Category 8.2 is terminated with the same connectors as Category 7(a), TERA & GG45. While all previous categories of balanced twisted-pair copper cabling have supported a maximum channel length of 100m, to support its maximum speed of 40Gbps, there is a limit to the channel length to the tune of 30m. For this reason, Category 8 is unlikely to be used as an installed cable, more for patching over short distances where fibre transceivers are more expensive than RJ45. Conclusion While there’s still a case for Category 5e to be installed, it’s certainly getting left behind with theoretical speed. At the current time, both Category 5e and Category 6 support a maximum of a Gigabit at 100M Channel Lengths (in mainstream active hardware [routers, switches, NICs]). While this, in theory, puts them on a level playing field. Category 6’s increased frequency, internal… Continue reading Category 5e, 6, 6A, 7, 8? – What’s the Difference?
Category 6 Installation in Northamptonshire – Team Prevent UK
Team Prevent UK approached Nene Data & Electrical Ltd due to their requirement for a new Category 6 infrastructure installation within their additional premises in Towcester, Northamptonshire Team Prevent UK is the UK division of Europes leading Occupational Health & Wellbeing providers, B·A·D GmbH. Established in 1975, they are able to provide Specialist Health, Well Being and Safety Services to over 250,000 companies and their 4 million employees across Europe. Due to recent rapid growth, Team Prevent UK have had a requirement for further premises to be acquired near to their current Center of Operations in Towcester. Once successfully located, Team Prevent UK reached out to Nene Data & Electrical for advice on whether to pursue a Category 5e or Category 6 cabling system. Nene Data & Electrical Ltd assigned their design team to the project to assess Team Prevent UK’s full needs. Due to the building lease term being of a substantial length, Nene Data & Electrical Ltd’s design team specified the Excel Networking Category 6 range for the horizontal cabling, and Excel’s Environ Rack series for the comms rack located within the main comms room. Excel’s cabling system provides Team Prevent UK with a manufacturer backed 25-year warranty which ensures that the IT Team have peace of mind that the cabling infrastructure has been installed to a high quality. Once awarded the contract, our installation team began the installation. The installation was completed just two weeks after the initial communication for the project happened, however under a tight deadline no quality was sacrificed and upon delivery, Sam Dummer, Contract Manager at Team Prevent UK expressed his gratefulness on the smooth and professional standard of the service the NDE Team delivered.
802.3bz – Breathing new life into Category 5e & 6 Infrastructure
Category 5e & 6 cabling has been the standard for cabling installation in businesses for over a decade however with the rise in wireless devices being deployed, Cat5e and Cat6 can no longer supply the required bandwidth for the latest generation of wireless access points bandwidth demands, this currently leaves only one solution, Category 6a. Category 6a offers a huge performance increase over Cat5e and Cat6 however it comes with a much larger CSA (Cross-Sectional Area) which increases the size of cable containment required but Cat6a also comes at an increased cost for the cable itself. This means that Cat6a is unachievable for many businesses and thus have settled for Cat5e or Cat6 installations. This issue has led many businesses to an issue that now needs resolving, how to get greater amounts of bandwidth to the end user, without expensive new cable runs. This issue was identified, and the 2.5G/5GBASE-T Task Force and started working on a resolution in March 2015. 18 months on and the solutions they proposed have been approved by the IEEE (Institute of Electrical and Electronics Engineers), the world’s largest association of technical professionals and one of the leading standards making organisations in the world. The solution they proposed utilised existing Category 5e and 6 infrastructures, however, they could increase speeds over already installed cables to up to 2.5Gbits/s over Category 5e and up to 5Gbit/s over Category 6! And these speeds can be delivered without compromising the ability to utilise Power-over-Ethernet. This means that the solution to providing greater bandwidth for the latest Wave 2 802.11AC Wireless Access Points has likely been found. But wait, a new standard has been released and it offers what many businesses require, but who’s supporting it? This is the question that our team kept coming back to, and thankfully the answer is, almost all the big names. With the likes of Cisco, Intel, Aquantia, Marvell and many more promoting and the likes of Fluke Networks, Brocade and Aruba also behind the project it won’t be long till we start seeing the adoption in hardware. So, we have the infrastructure to support it, the hardware is on its way, surely we’re ready to go? Well, many cabling vendors, including world leading Excel Networking have raised concerns regarding the cables ability, stating “these Categories of cabling are now going to be asked to support parameters they were never designed for” and that “the Category 5e cable we installed 10 years ago, as well as the way it was installed, is not the same as what we have and do today, purely because we have had 10 years to learn and make improvements in both aspects.”. So although we’ve seen a saving grace for existing infrastructure, the jury is still out to see how performance works in the real world.
